Related Experiment Video
Updated: Jun 19, 2026

08:28
Monitoring the Wall Mechanics During Stent Deployment in a Vessel
Published on: May 8, 2012
9.4K
The NeVa Net stent-retriever - initial report of 20 cases from two high volume centres
Pervinder Bhogal1, Marco Mancuso-Marcello1, Rory Fairhead1
1Department of Interventional Neuroradiology, The Royal London Hospital, Whitechapel Road, London, E1 1BB, UK.
Acta Neurochirurgica
|July 15, 2025
Summary
The novel NeVa NET stent-retriever, designed with a microfiltration net, achieved a 94% first-pass recanalization rate in stroke patients. This technology shows promise in preventing distal embolization during mechanical thrombectomy.
Area of Science:
- Interventional Neurology
- Medical Device Technology
- Cerebrovascular Disease Management
Background:
- Mechanical thrombectomy is crucial for acute ischemic stroke treatment, with first-pass recanalization significantly impacting patient outcomes.
- Novel stent-retrievers aim to improve procedural efficiency and reduce complications like distal embolization.
Purpose of the Study:
- To evaluate the initial clinical experience and safety of the NeVa NET stent-retriever, a new device featuring an integrated distal microfiltration net.
- To assess the efficacy of the NeVa NET in achieving first-pass recanalization and preventing embolic complications in stroke patients.
Main Methods:
- A retrospective review of prospectively maintained databases identified 20 patients treated with the NeVa NET 4x30mm device.
- Data collected included baseline demographics, stroke severity (NIHSS, ASPECT), clot characteristics, procedural outcomes (eTICI scores), complications, and 90-day modified Rankin Scale (mRS) scores.
Main Results:
- The NeVa NET was successfully tracked in 18 out of 20 patients.
- A high first-pass recanalization rate (eTICI ≥ 2c) of 94% was observed, with a final recanalization rate of 94%.
- No new emboli to distal territories, vessel ruptures, or dissections were reported. 50% of patients achieved a favorable outcome (mRS 0-2).
Conclusions:
- The NeVa NET stent-retriever, with its unique design for preventing distal embolization, demonstrated a very high rate of first-pass and final successful recanalization in this initial patient cohort.
- This novel technology shows potential for improving mechanical thrombectomy outcomes, and further investigation in larger studies is warranted.
Related Concept Videos
Single Nucleotide Polymorphisms-SNPs
A single nucleotide polymorphism or SNP is a single nucleotide variation at a specific genomic position in a large population. It is the most prevalent type of sequence variation found in the human genome. Point mutations that occur in more than 1% of the population qualify as SNPs. These are present once every 1000 nucleotides on an average in the human genome. Replacement of a purine with another purine (A/G) or a pyrimidine with another pyrimidine (C/T) is known as a transition. In contrast,...
Investigation of Disease Outbreaks
Multistate foodborne outbreaks pose significant public health risks and require meticulous investigation to identify sources and implement control measures. The Centers for Disease Control and Prevention (CDC) utilizes a dynamic seven-step process for these investigations, integrating data from laboratories, interviews, and environmental assessments to protect public health.Outbreak Detection: The detection of multistate outbreaks typically begins with PulseNet, the CDC's national laboratory...