Joint inversion of transient electromagnetic and radiomagnetotelluric data for enhanced subsurface characterization

Ismael M Ibraheem1, Pritam Yogeshwar2, Fereydoun Sharifi3

  • 1Institute of Geophysics and Meteorology, University of Cologne, Pohligstrasse 3, 50969, Cologne, Germany. ismael.ibraheem@geo.uni-koeln.de.

Scientific Reports
|July 15, 2025
PubMed
Abstract

Related Concept Videos

Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.1K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.2K
Magnetic Susceptibility and Permeability01:31

Magnetic Susceptibility and Permeability

In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
1.4K
Divergence and Curl of Magnetic Field01:26

Divergence and Curl of Magnetic Field

The magnetic field due to a volume current distribution given by the Biot–Savart Law can be expressed as follows:
3.2K
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
226
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
760