Related Experiment Video
Updated: Sep 15, 2025

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Direct determination of rare earth elements in atmospheric precipitation using a membrane desolvation ICP-MS/MS with
Jiang-Yi Zhang1,2, Wen-Jing Liu3,2, Di Liu4
1Institutional Center for Shared Technologies and Facilities, Institute of Geology and Geophysics, Chinese Academy of Sciences Beijing 100029 China liuwenjing@mail.iggcas.ac.cn.
Abstract:
Analyzing rare earth elements (REEs) in atmospheric precipitation can reveal their sources and migration patterns. However, their direct determination in atmospheric precipitation using ICP-MS/MS remains challenging owing to low (sub-ng L-1) levels and mass spectral interference. This study established a reliable ICP-MS/MS method using a membrane desolvation system to enhance the sensitivity of REEs detections and employing N2O as the reaction gas to eliminate spectral interference for the direct measurement of REEs in atmospheric precipitation. The production rates of REE monoxides were significantly enhanced when using N2O as the reaction gas instead of O2. In particular, the yield of EuO+ increased to 64.9%, while that of YbO+ increased to 39.5%. A regular 10% signal suppression of REE+ was observed in the presence of matrix using membrane desolvation and employing 185Re as an internal standard effectively improved the results by >98%. The instrumental detection limits of the proposed method ranged from 0.001 ng L-1 for Lu to 0.022 ng L-1 for Nd. The results for REEs in the certified reference material (SLRS-6) at a 1 : 10 dilution was consistent with the values reported in the literature. Thus, the proposed method was employed to analyze atmospheric precipitation samples. The accuracy of the results demonstrated that this method has the potential for routinely measuring sub ng L-1 levels of REEs in freshwater samples, offering advantages regarding sample throughput and reduced handling.
More Related Videos
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Precipitation and Co-precipitation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences