Related Experiment Video
Updated: May 1, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Three-Dimensional Quantification of Macular OCT Alterations Improves the Diagnostic Performance of Artificial
Lukas Heine1,2, Anna Vahldiek1, Benja Vahldiek1
1Institute for AI in Medicine, University Medicine Essen, Essen, North-Rhine Westfalia, Germany.
Purpose:
To evaluate the performance of state-of-the-art semantic segmentation methods on OCT data for age-related macular degeneration (AMD). We measured variability between annotators to quantify differences in ground truth arising from personal bias.
Methods:
From 94 patients suffering from exudative neovascular AMD (nAMD), 24 volume scans (49 slices each) were selected. Trained members of a reading center for AMD created pixel-wise masks for 12 retinal layers and two pathological labels (fluid, hyperreflective material) to benchmark two-dimensional (2D) and three-dimensional (3D) segmentation models on clinical data. Models were evaluated using fivefold cross-validation, and the best model was used to quantify errors between ground truth and predictions.
Results:
The nnU-Net (3D) achieves the best segmentation performance (mean Dice similarity coefficient [DSC] of 0.907), leaving a theoretical gap of 0.036 DSC to the mean interrater agreement, which is the upper bound of model performances. Comparing the volumes calculated for each structure using the model masks with the ground truth produced an average error of 0.065 mm3.
Conclusions:
Models like nnU-Net can produce high-quality 3D masks, challenging the conventional reliance on 2D slices for optimal performance. Both DSC and low average errors indicate that such a model is fit for the large-scale analysis of cohorts.
Translational Relevance:
The presented approach can streamline clinical workflows by reducing the time and effort required for manual annotations, ultimately supporting more efficient and accurate monitoring of AMD progression and treatment response. We provide open-source access to the model weights, annotation instructions and sample data.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography

