Diagnostic Efficacy of PET/CT-Aided versus Conventional CT-guided Lung Biopsy: A Systematic Review and Meta-Analysis
Yeonhee Lee1, Sowon Jang2, Minseon Kim2
1Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea.
Introduction:
Unlike its well-established role in lung cancer staging, positron emission tomography /computed tomography (PET/CT)'s role in guiding lung biopsies remains unclear and underutilized, despite its potential to distinguish metabolically active regions from areas of necrosis or fibrosis within lesions.
Objective:
This study aims to assess the diagnostic efficacy of PET/CT-aided versus conventional CT-guided lung biopsy by comparing the incidences of non-diagnostic results, false results, and complications.
Methods:
Studies comparing PET/CT-aided and conventional CT-guided lung biopsy were identified through an intensive search of PubMed, Embase, and the Cochrane Library. Data on nondiagnostic results, false results, and complications were extracted. Risk ratios (RRs) with 95% confidence intervals (CIs) were calculated using a random-effects model.
Results:
Seven studies involving 1,661 procedures were included. PET/CT-aided lung biopsy significantly reduced nondiagnostic results compared to conventional CT-guided biopsy (2.8% vs. 9.1%; pooled RR: 0.38, 95% CI: 0.20–0.70, P = 0.002). False results were also significantly fewer in the PET/CT-aided group (6.5% vs. 17.0%; pooled RR: 0.48, 95% CI: 0.35–0.65, P < 0.001). There was no statistically significant difference in overall complication rates (28.1% vs. 32.5%; pooled RR: 0.92, 95% CI: 0.77–1.10, P = 0.352), while PET/CT-aided biopsy showed a slight tendency toward fewer major complications (0.9% vs. 1.7%; pooled RR: 0.67, 95% CI: 0.30–1.44, P = 0.303).
Conclusion:
PET/CT-aided CT-guided lung biopsy offers advantages over conventional CT-guided lung biopsy by significantly reducing nondiagnostic and false results, without significant differences in the risk of complications.
More Related Videos
06:03Use of Electromagnetic Navigational Transthoracic Needle Aspiration E-TTNA for Sampling of Lung Nodules
Published on: May 23, 2015
11:31Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care