A Buccal Mucosal Oximeter Accurately Measures Arterial Oxyhemoglobin Saturation
Connor Snow1,2,3, Shane Magnison-Benoit1,2,3, Matiram Pun1,2,3
1Department of Physiology and Pharmacology, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.
Purpose:
While arterial oxyhemoglobin saturation (SaO2) decreases during sleep in many patients with sleep apnea and pulmonary diseases, personalized oximeters suitable for multi-night monitoring of SpO2 are not readily available. The present report describes a custom buccal mucosal intraoral oximeter that might provide the opportunity for such long-term monitoring given its strong accuracy in measuring SpO2 over a range of clinically relevant hypoxemia.
Patients And Methods:
The intraoral buccal mucosal oximeter was constructed by encapsulating a reflectance pulse oximeter in an overlay of the maxillary dentition. Accuracy was assessed during non-motion conditions in normal participants (n = 12) made progressively hypoxic by decreasing the partial pressure of end-tidal oxygen (PETO2). CO-oximeter values of SaO2 from arterial blood constituted the "gold standard" for comparison with the buccal mucosal oximeter's values. The oximeter's pulse rate and an electrocardiogram (ECG) determined heart rate were also compared.
Results:
Analysis of 325 paired SaO2 values from the CO-oximeter and buccal mucosal oximeter yielded the following: r = 0.95; bias = 0.72; and accuracy root-mean-square (ARMS) = 2.94%. Results from the pulse rate/ECG analysis were: r = 0.99; bias = 0.30; and ARMS = 2.08 bpm.
Conclusion:
These results reveal robust accuracy of the buccal mucosal oximeter measurement of SaO2 and pulse rate, as shown by good agreement with a "gold standard" over a wide range of arterial hypoxemia. Such clinically acceptable accuracy indicates that this novel reflectance oximeter may prove useful in management of patients with sleep-induced hypoxemia by allowing for long-term monitoring of SaO2.
More Related Videos
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
