Ultrasonography in granulomatous mastitis: diagnostic differentiation, treatment response, and prognostic value
Xiaoli Feng1, Honglei Zhang1, Qiusheng Chang1
1Department of Ultrasonography, The Sixth People's Hospital of Hengshui Hengshui 053200, Hebei, China.
Objective:
This study aimed to evaluate the diagnostic value of ultrasonography in distinguishing granulomatous mastitis (GM) from ductal carcinoma in situ (DCIS), and to assess its prognostic relevance in monitoring treatment response and predicting recurrence.
Methods:
In this retrospective study, we analyzed conventional B-mode ultrasound and contrast-enhanced ultrasound (CEUS) features in 146 patients with histologically confirmed GM and 140 with DCIS. Key comparisons included: (1) B-mode characteristics (lesion morphology, posterior acoustic features, microcalcifications, vascular patterns, etc.); (2) CEUS quantitative parameters [mean transit time (mTTI), time to peak, rise time, etc.]. Clinical treatment responses and recurrence data were also collected for GM patients.
Results:
GM exhibited distinct ultrasound characteristics compared to DCIS, including more frequent posterior acoustic enhancement (58.90% vs. 12.14%), absence of microcalcifications (82.19% vs. 49.29%), and a higher prevalence of marginal or mixed vascular patterns (83.02% vs. 73.34%) (all P < 0.001). On CEUS, GM demonstrated shorter mTTI but higher peak enhancement, wash-in, and wash-out rates than DCIS (all P < 0.001). Among the GM cohort, 121 of 146 patients achieved clinical cure. These cured patients had significantly lower pretreatment mTTI values (P < 0.001), and mTTI demonstrated predictive value for treatment response (area under the ROC curve = 0.765; sensitivity: 68.0%, specificity: 86.0%). During one-year follow-up, 15 of the 121 cured patients experienced recurrence (12.40%). The presence of ductal dilatation on ultrasound was associated with a higher recurrence rate.
Conclusion:
Ultrasound, particularly when combined with CEUS parameters, not only facilitates the differentiation of GM from DCIS but also serves as a valuable tool for evaluating treatment response and predicting recurrence in GM patients.
More Related Videos
07:25Author Spotlight: A Focus on Standardized Salivary Gland Ultrasound Protocol in Connective Tissue Disease Research
Published on: October 13, 2023
10:04Analysis of 18FDG PET/CT Imaging as a Tool for Studying Mycobacterium tuberculosis Infection and Treatment in Non-human Primates
Published on: September 5, 2017
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography