[Distal Stent Graft-induced New Entry on the Lesser Curvature of Distal Aortic Arch:Report of a Case]

Toshifumi Saga1, Masataka Koga, Shoichiro Izuka

  • 1Department of Cardiovascular Surgery, Kanto Central Hospital, Tokyo, Japan.

Insights

A rare case of distal stent graft-induced new entry (dSINE) occurred on the lesser curvature of the aorta after frozen elephant trunk (FET) repair. Further thoracic endovascular aortic repair (TEVAR) was successful.

Area of Science:

  • Cardiovascular Surgery
  • Vascular Surgery
  • Aortic Aneurysm Research

Background:

  • Dissecting thoracic aortic aneurysms require complex surgical repair.
  • The frozen elephant trunk (FET) technique is a common approach for total aortic arch replacement.
  • Stent graft-induced complications can occur after endovascular repair.

Purpose of the Study:

  • To report a rare case of distal stent graft-induced new entry (dSINE) on the lesser curvature of the distal aortic arch.
  • To discuss the potential mechanisms behind dSINE occurring on the lesser curvature.
  • To highlight the successful management of this rare complication.

Main Methods:

  • A 62-year-old male patient with cerebral hemorrhage and dissecting thoracic aortic aneurysm underwent total arch replacement with FET.
  • Postoperative follow-up included enhanced computed tomography (CT) scans.
  • Diagnosis of dSINE led to subsequent thoracic endovascular aortic repair (TEVAR).

Main Results:

  • Enhanced CT at 31 months revealed a dSINE on the lesser curvature of the distal arch, a rare location.
  • The patient successfully underwent additional TEVAR to address the dSINE.
  • The case presents a unique instance of dSINE on the aortic lesser curvature.

Conclusions:

  • dSINE on the lesser curvature after FET repair is a rare but significant complication.
  • Understanding the specific mechanisms of dSINE on the lesser curvature is crucial for prevention and management.
  • TEVAR can be an effective treatment for dSINE in this location.