Related Experiment Video
Updated: Sep 15, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Impact of x rays on the sensitivity of CR-39 detectors to 2.4-MeV protons
R Kishimori1, M Cufari1, E Z L Zhong-Johnson2
1Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA.
Abstract:
Solid-state nuclear track detectors, such as CR-39, lose sensitivity when subjected to doses of x rays on the order of 1 Gy in nuclear-fusion relevant experiments. As a result, the formed tracks have, in general, smaller maximum radii and shallower maximum depths. Presented here are experiments using atomic force microscopy to measure the CR-39 sensitivity parameter Vt/Vb, the ratio of track to bulk etch rates, for ∼2.4 MeV protons. The measurements revealed that absorbed x-ray doses of the order of 1 Gy reduced the CR-39 track diameters by a factor of 3 from ∼1200 to ∼400 nm and reduced the track depths by an order of magnitude from ∼550 to ∼50 nm. The corresponding change in the sensitivity parameter was inferred and found to have substantially decreased from ∼1.1 to ≲1.01. Doses in excess of 0.5 Gy reduced the track diameter, at an etch time of 2 h, below the 1.0 μm limit typical of optical microscopy methods used when scanning large, i.e., ≳25 cm2, samples of CR-39. The findings suggest that the mechanism of sensitivity loss is driven by x-ray induced cross-linking of the bulk CR-39. The enhanced cross-linking reduces the solubility of the material along charged-particle trajectories compared with that of the bulk material. Representative absorbed doses of between 0.01 and 1 Gy in CR-39 on OMEGA and NIF in typical experimental configurations are then compared with the results.
More Related Videos
Related Concept Videos
X-ray Imaging
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Biological Effects of Radiation
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...

