Strategies for Optimization of Cryogenic Electron Tomography Data Acquisition
Published on: March 19, 2021
Towards continuous time-dependent tomography: implementation and evaluation of continuous acquisition schemes in
Timothy M Craig1, Robin Girod1, Gail Vinnacombe-Willson2
1EMAT and NANOlight Center of Excellence, University of Antwerp, Groenenborgerlaan 171, Antwerp B-2020, Belgium.
None:
Electron tomography is a microscopy technique that allows the three-dimensional (3D) characterization of nanomaterials by reconstructing a 3D volume from a series of two-dimensional (2D) projection images acquired at different viewing angles. In a transmission electron microscope (TEM), the change in angle is achieved by tilting the sample holder and conventionally follows an incremental tilt scheme. Images are typically acquired between ± 60-80°, as dictated by the TEM geometry, and in small, 2-3°, increments to minimize sample shifts and facilitate acquisition and post-processing. This tilt scheme unfortunately performs poorly when time resolution is necessary, i.e., when as many 3D reconstructions as possible of the same object within a given time are desired. Golden ratio scanning (GRS) and binary decomposition (BD) have been proposed in other tomographies because they allow consecutive reconstructions to share some projections. However, due to practical considerations, they have seen limited usage in electron tomography. In this work, we present optimized implementations of GRS and BD for electron tomography with corrections for alignment, backlash, and angular uniformity. These tilt schemes were compared with incremental acquisition for simulated and experimental datasets in static or dynamic contexts. Experimentally, GRS and BD required 2-3 times longer acquisition time, and resulted in a 2 times increase in electron dose compared to the incremental scheme, thus confirming the incremental scheme as the method to be favored for static applications. In dynamic applications, our results suggest that a time vs. spatial resolution tradeoff should be considered. Nonetheless, GRS and BD schemes would achieve up to 30x higher 3D frame rate, showing promise toward time-dependent electron tomography.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...