Related Experiment Video
Updated: Sep 14, 2025

Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation
Published on: March 17, 2023
Emergent Transcatheter Tricuspid Edge-to-Edge Repair for Right Ventricular Shock From Tricuspid Regurgitation in
Nicholas J Valle1, Amin Yehya2, Animesh Rathore3
1Eastern Virginia Medical School, Macon and Joan Brock Virginia Health Sciences at Old Dominion University, Internal Medicine Residency Program, Norfolk, Virginia, USA.
Background:
Transcatheter tricuspid edge-to-edge repair (T-TEER) is an emerging technology used to treat severe tricuspid regurgitation (TR). The pivotal trials demonstrating the safety and efficacy of T-TEER exclude patients with severely reduced left ventricular function (≤20%).
Case Summary:
We demonstrate the use of T-TEER in a patient with end-stage hypertrophic cardiomyopathy who suffered acute, torrential TR and subsequently developed cardiogenic shock as a complication of high-risk transvenous lead extraction.
Why Beyond The Guidelines:
Currently, there are no guidelines addressing the nonsurgical emergent management of acute TR.
Discussion:
The TriClip system (Abbott) may have certain advantages when used in managing acute primary TR compared with other valve repair and/or replacement approaches.
Take-Home Message:
TriClip can be considered for urgent use to correct severe TR in hemodynamically unstable patients who are not surgical candidates.