Characterizing and minimizing uncertainties in diagnostic X-ray beam calibrations using a Monte Carlo-based model and
Abdelouahab Abarane1, Mustapha Bougteb2, Taibi Zidouz3,4
1Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Hassan First University, Higher Institute of Health Sciences, 26000, Settat, Morocco. a.abarane@uhp.ac.ma.
None:
This study aims to develop a flexible Geant4 application capable of modeling all IEC 61267 defined radiation qualities for the HOPEWELL Designs 225 kV X-ray generator, while systematically analyze the impact of various environmental and systematic factors. Using Geant4, we replicated the experimental setup of the LEGEX laboratory and simulated all IEC 61267 radiation qualities by adjusting relevant beam parameters. The model was validated by comparing simulated HVLs and spectra, measured with a CdTe X-123 spectrometer against experimental data, SRS78 software results, and IEC reference values. The simulation demonstrated strong agreement with experimental measurements and published data, confirming the validity of our Geant4 application. We derived the function that characterizes the behavior of Kinetic Energy Released per unit Mass (KERMA) in response to variations in each influencing factor. Geometrical misalignment is the primary contributor to deviations, followed by aluminum purity and diaphragm movement, while environmental factors induced minor fluctuations. Additionally, we quantified backscattered radiation and applied corrective measures to eliminate its impact on measurements. The developed Geant4 application provides a reliable tool for simulating IEC 61267 radiation qualities and optimizing dosimetric accuracy. Our framework offers a cost-effective alternative to replicate different scenarios multiple times to identify and minimizes uncertainties.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Uncertainty in Measurement: Reading Instruments
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Uncertainty in Measurement: Accuracy and Precision