Value of contrast-enhanced ultrasound combined with shear wave elastography in differentiating xanthogranulomatous
Junjie Chen1, Caifeng Liu2, Shujie Pang3
1Department of Radiology, Shanghai Eastern Hepatobiliary Surgery Hospital, Third Affiliated Hospital of Naval Medical University, Naval Medical University, Shanghai 200438, China; Department of Ultrasound, Shanghai Yida Hospital, Shanghai 201799, China.
Objectives:
To evaluate the value of contrast-enhanced ultrasound (CEUS) combined with two-dimensional shear wave elastography (2D-SWE) in the differential diagnosis of xanthogranulomatous cholecystitis (XGC) and gallbladder carcinoma (GBC).
Methods:
This study included 90 patients who underwent surgical treatment from December 2021 to September 2023. Pathological results divided them into XGC (22 cases) and GBC (68 cases) groups. Both groups underwent 2D, 2D-SWE, and CEUS for the differential diagnosis of XGC and GBC. 2D-SWE assessed the uniformity pattern, margin, and pericholecystic enlargement, while the CEUS analyzed the GB mucosal line, hypo-echoic nodules, vascular imaging types, and enhancement patterns.
Results:
The 2D-SWE assessment revealed that heterogeneity, irregularity, and pericholecystic enlargement were more common in the GBC group than in the XGC group (p < 0.001). Quantitative analysis revealed a significantly higher GB/liver stiffness ratio in GBC than in XGC (p < 0.001). As assessed through CEUS, the XGC group was characterised by synchronised wash-in and slow wash-out (p < 0.001). The GBC group showed 'rapid wash-in and rapid wash-out' mode (p < 0.001). The diagnostic sensitivity, specificity, and accuracy of differentiating XGC lesions from those of GBC using CEUS combined with 2D-SWE were higher than those of either method alone, which were 91.0 %, 90.9 %, and 90.9 %, respectively.
Conclusions:
CEUS combined with 2D-SWE improved the diagnostic efficiency of XGC and GBC, with high sensitivity, specificity, and accuracy.
Clinical Relevance Statement:
CEUS combined with 2D-SWE improved the diagnostic efficiency of XGC and GBC with higher sensitivity, specificity, and accuracy.
More Related Videos
07:44Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
04:03Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery
Published on: March 28, 2025
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...