Related Experiment Video
Updated: Sep 14, 2025

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Ultra-low dose imaging in a standard axial field-of-view PET
Thiago Lima1,2,3, Carlos Vinícius Gomes1, Paul Fargier3
1Department of Radiology and Nuclear Medicine, Luzerner Kantonsspital, University Teaching and Research Hospital, University of Lucerne, Lucerne, Switzerland.
Abstract:
Though ultra-low dose (ULD) imaging offers notable benefits, its widespread clinical adoption faces challenges. Long-axial field-of-view (LAFOV) PET/CT systems are expensive and scarce, while artificial intelligence (AI) shows great potential but remains largely limited to specific systems and is not yet widely used in clinical practice. However, integrating AI techniques and technological advancements into ULD imaging is helping bridge the gap between standard axial field-of-view (SAFOV) and LAFOV PET/CT systems. This paper offers an initial evaluation of ULD capabilities using one of the latest SAFOV PET/CT device. A patient injected with 16.4 MBq 18F-FDG underwent a local protocol consisting of a dynamic acquisition (first 30 min) of the abdominal section and a static whole body 74 min post-injection on a GE Omni PET/CT. From the acquired images we computed the dosimetry and compared clinical output from kidney function and brain uptake to kidney model and normal databases, respectively. The effective PET dose for this patient was 0.27 ± 0.01 mSv and the absorbed doses were 0.56 mGy, 0.89 mGy and 0.20 mGy, respectively to the brain, heart, and kidneys. The recorded kidney concentration closely followed the kidney model, matching the increase and decrease in activity concentration over time. Normal values for the z-score were observed for the brain uptake, indicating typical brain function and activity patterns consistent with healthy individuals. The signal to noise ration obtained in this study (13.1) was comparable to the LAFOV reported values. This study shows promising capabilities of ultra-low-dose imaging in SAFOV PET devices, previously deemed unattainable with SAFOV PET imaging.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography