Myopic versus perfect foresight target setting for Indonesia's net zero electricity transition
Bintang Yuwono1,2, Lukas Kranzl1, Reinhard Haas1
1Energy Economics Group (EEG), Institute of Energy Systems and Electrical Drive, Technischen Universität Wien (TU Wien), Vienna 1040, Austria.
Iscience
|July 21, 2025
Summary
Setting short-term emissions targets can be cheaper but risks increased fossil fuel use. Combining less drastic emissions goals with renewable energy policies is essential for sustainable energy systems.
Area of Science:
- Energy Systems Analysis
- Climate Change Mitigation Policy
- Economic Modeling
Background:
- International climate agreements, like the Paris Agreement, necessitate setting emissions targets.
- Current decision-making often focuses on short-term milestones, potentially overlooking long-term implications.
- The choice between myopic (short-sighted) and perfect foresight (long-term) approaches to target setting has economic and environmental consequences.
Purpose of the Study:
- To investigate the cost implications of setting emissions targets based on myopic versus perfect foresight.
- To analyze the trade-offs between cost minimization and emissions reduction strategies in long-term energy planning.
- To evaluate the role of renewable energy policies in mitigating risks associated with myopic emissions targets.
Main Methods:
- Utilized a long-term energy system optimization model.
- Employed mixed-integer linear programming (MILP) to simulate perfect foresight scenarios.
- Compared emissions outcomes and costs derived from perfect foresight with myopic, exogenous target values.
Main Results:
- Significant cost discrepancies exist between myopic and perfect foresight emissions targets.
- Myopic approaches, avoiding drastic emissions reductions, show lower immediate cost discrepancies compared to perfect foresight.
- Lenient emissions targets under a myopic approach risk increased reliance on fossil power generation.
Conclusions:
- Myopic emissions target setting can lead to suboptimal long-term energy system configurations.
- While seemingly cost-effective in the short term, myopic strategies may increase fossil fuel dependency.
- Integrating ambitious renewable energy promotion policies with less drastic emissions reduction targets is crucial to balance costs and sustainability.
Related Concept Videos
Power Factor Correction
267
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
267
Electrical Power
3.2K
Electric power is the product of current and voltage, represented in units of joules per second, or watts. For example, cars often have one or more auxiliary power outlets with which you can charge a cell phone or other electronic devices. These outlets may be rated at 20 amps and 12 volts, so that the circuit can deliver a maximum power of 240 watts. Consider a 25 Watt bulb and a 60 Watt bulb. The conversion of electrical energy produces heat and light, while the kinetic energy lost by the...
3.2K
Power Factor
454
The power factor is defined as the ratio of average (or active) power to apparent power, as illustrated by the relation
454
Focusing of Light in the Eye
3.2K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
3.2K
Load-frequency control
260
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
260
Reducing Line Loss
195
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
195


