Related Experiment Video
Updated: Sep 14, 2025

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Chairside vs Prefabricated Sealing Socket Abutments for Posterior Immediate Implants: A Randomized Clinical Trial
Vitālijs Gnusins1, Samuel Akhondi2, Tadas Zvirblis3
1Private Practice, Adenta Clinic, Riga, Latvia.
Objectives:
This randomized clinical trial aimed to compare changes in soft tissue height, probing depth, and buccal contour volume loss following immediate implant placement using either chairside composite or prefabricated zirconia Sealing Socket Abutments (SSAs) in the posterior region.
Materials And Methods:
47 patients requiring posterior tooth extraction and immediate implant placement were randomly assigned to one of two groups: the composite Sealing Socket Abutment (CS) group (n = 24), receiving chairside-fabricated abutments, or the zirconia Sealing Socket Abutment (ZR) group (n = 23), receiving prefabricated abutments. Implants were placed immediately after extraction, using static computer-assisted implant surgery (sCAIS). Supra-Platform Tissue Height (SPTH) and total horizontal tissues (THT) were assessed using cone-beam computed tomography (CBCT) over a 3-month healing period. Implant survival, probing pocket depths (PPD), bleeding on probing (BOP) and plaque index (PI) were recorded clinically, while volumetric analysis was performed using digital impressions.
Results:
SPTH remained stable from baseline to the 3-month follow-up, with a mean change of -0.17 mm in the CS group and -0.44 mm in the ZR group. These differences were not statistically significant (p > 0.05). THT exhibited significant horizontal shrinkage in both groups over the 3-month period. In the CS group, THT decreased by 1.00 mm, while the ZR group showed a reduction of 1.17 mm (p < 0.001). PPD increased in the CS group from 2.8 mm to 3.7 mm on the palatal/lingual aspect and from 2.5 mm to 3.2 mm on the buccal aspect (p = 0.026). In contrast, the ZR group showed a decrease from 3.1 mm to 2.7 mm palatally/lingually and remained stable buccally at 2.6 mm to 2.7 mm (p = 0.001). BOP in the CS group decreased from 42.3% to 7.7% (p = 0.009), while the ZR group maintained low BOP levels, decreasing slightly from 17.4% to 4.4% (p = 0.346).
Conclusions:
Both approaches showed comparable outcomes. ZR abutments resulted in shallower probing depths, while CS abutments showed less volumetric shrinkage. SPTH remained stable in both groups.
Trial Registration:
This trial was registered prior to patient enrollment at ClinicalTrials.gov identifier: NCT05748379.