Related Experiment Video
Updated: Sep 14, 2025

Biomechanical Changes Related to Low Back Pain: An Innovative Tool for Movement Pattern Assessment and Treatment Evaluation in Rehabilitation
Published on: December 13, 2024
Deep learning algorithm for the automatic assessment of axial vertebral rotation in patients with scoliosis using the
Jeoung Kun Kim1, Ming Xing Wang2, Donghwi Park3
1Department of Business Administration, School of Business, Yeungnam University, Gyeongsan-si, Republic of Korea.
Abstract:
Accurate assessments of axial vertebral rotation (AVR) is essential for managing idiopathic scoliosis. The Nash-Moe classification method has been extensively used for AVR assessment; however, its subjective nature can lead to measurement variability. Therefore, herein, we propose an automated deep learning (DL) model for AVR assessment based on posteroanterior spinal radiographs. We develop a two-stage DL framework using the MMRotate toolbox and analyze 1080 posteroanterior spinal radiographs of patients aged 4-18 years. The framework comprises a vertebra detection model (864 training and 216 validation images) and a pedicle detection model (14,608 training and 3652 validation images). We improved the Nash-Moe classification method by implementing a 12-segment division system and width ratio metric for precise pedicle assessment. The vertebra and pedicle detection models achieved mean average precision values of 0.909 and 0.905, respectively. The overall classification accuracy was 0.74, with grade-specific performance between 0.70 and 1.00 for precision and 0.33 and 0.93 for recall across Grades 0-3. The proposed DL framework processed complete posteroanterior radiographs in < 5 s per case compared with conventional manual measurements (114 s per radiograph). The best performance was observed in mild to moderate rotation cases, with performance in severe rotation cases limited by insufficient data. The implementation of DL framework for the automated Nash-Moe classification method exhibited satisfactory accuracy and exceptional efficiency. However, this study is limited by low recall (0.33) for Grade 3 and the inability to classify Grade 4 towing to dataset constraints. Further validation using augmented datasets that include severe rotation cases is necessary.
More Related Videos
07:44Evaluation of Patients' Posture and Gait Profile After Lumbar Fusion Surgery by Video Rasterstereography and Treadmill Gait Analysis
Published on: March 23, 2019
06:30Assessment of Static Graviceptive Perception in the Roll-Plane using the Subjective Visual Vertical Paradigm
Published on: April 28, 2020
Related Concept Videos
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Eccentric Axial Loading in a Plane of Symmetry
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...