Related Experiment Video
Updated: Sep 14, 2025

Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Association of Two Preoxygenation Approaches With Hypoxemia During Tracheal Intubation: A Secondary Analysis
Christopher D Chou1, Jessica A Palakshappa1, HarLeigh Haynie1
1Department of Medicine, Section of Pulmonary, Critical Care, Allergy and Immunologic Disease, Wake Forest School of Medicine, Winston-Salem, NC; Department of Biostatistics (Haynie, Garcia, Long), Wake Forest School of Medicine, Winston-Salem, NC.
Study Objectives:
Oxygen masks (bag-valve-mask device and nonrebreathing facemask oxygen) are the most common method of preoxygenation in critically ill patients undergoing emergency tracheal intubation in the emergency department and intensive care unit. Whether the type of oxygen mask used for preoxygenation alters the risk of hypoxemia during intubation is uncertain. We sought to compare the incidence of hypoxemia during intubation in patients preoxygenated with a bag-valve-mask device to the incidence of hypoxemia in patients preoxygenated with facemask oxygen.
Methods:
We conducted a secondary analysis of 2 randomized trials of emergency tracheal intubation. The primary outcome of hypoxemia was defined as a peripheral oxygen saturation <85% between induction of anesthesia and 2 minutes after tracheal intubation. We used a propensity-weighted multivariable logistic regression model to compare the incidence of hypoxemia between groups. We hypothesized that preoxygenation with a bag-valve-mask device would be associated with a lower incidence of hypoxemia compared to preoxygenation with facemask oxygen.
Results:
We included 1,156 patients in this analysis, of whom 136 were preoxygenated with a bag-valve-mask device and 1,020 were preoxygenated with facemask oxygen. Hypoxemia occurred in 20 of 136 (14.7%) participants in the bag-valve-mask device group and 153 of 1,020 (15.0%) participants in the facemask oxygen group. In the multivariable analysis, participants preoxygenated with a bag-valve-mask device had similar odds of hypoxemia to those preoxygenated with facemask oxygen (adjusted odds ratio 1.22, 95% confidence interval 0.72 to 2.16).
Conclusion:
In critically ill patients undergoing tracheal intubation, preoxygenation with a bag-valve-mask device did not reduce the risk of hypoxemia compared to preoxygenation with facemask oxygen.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....