Toward a Self-Inflating Bag Mechanical Ventilator, Maturation in Continuous Use, Safety, and Repeatability for
Noe Rodriguez1, Carlos Rubio1, Leonardo Barriga1
1Center for Engineering and Industrial Development, Queretaro, Mexico.
Background:
Researchers proposed mechanical ventilators (MVs) based on the automated compression of a self-inflating bag (SIB) to save lives during the pandemic caused by the SARS-CoV-2 virus. Many proposals had problems with continuous use time, repeatability of ventilatory variables, high partial pressure of carbon dioxide (PaCO2) values, and a decreasing fraction of inspired oxygen (FiO2) for high respiratory rates.
Objective:
This study aimed to demonstrate that our technology, based on automated compression of an SIB, can operate for several days, is repeatable in its ventilatory variables, and is safe in the ventilator-patient interaction.
Materials And Methods:
Ehecatl-4T (EHT) MV was based on SIB. We first validated the repeatability of the ventilatory variables using a lung simulator for different compliances (0.01 up to 0.05 L/cmH2O) and resistances (5 up to 50 cmH2O·s/L). Subsequently, we conducted a long-term durability test to maintain the ventilatory parameters. Finally, the EHT was tested in a preclinical study using 12 York-Landrace × Pietrain-Duroc pigs weighing 87 ± 5 kg. Six pigs were assigned to the experimental group and six were assigned to the reference group.
Results:
The EHT presented a relative error within the allowed margin for both pressure and volume modes. The EHT was operated for over 32 days without affecting the ventilatory variables. In the preclinical study, the PaCO2 and FiO2 values were close to the reference levels.
Conclusion:
The EHT showed potential for continuous use, demonstrating repeatability for ventilatory variables in bench testing. Clinical parameters were maintained according to the industry safety standards.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management