Related Experiment Video
Updated: Sep 14, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Comparative Efficacy and Safety of 0.8-L Versus 2-L Polyethylene Glycol-Ascorbic Acid Solutions in Colonoscopy
Bomee Lee1, Bora Keum1, Sung Noh Hong2
1Department of Internal Medicine, Division of Gastroenterology and Hepatology, Korea University College of Medicine, Seoul, South Korea.
Background And Aim:
High-volume polyethylene glycol (PEG) solutions are associated with low patient compliance, whereas low-volume alternatives pose higher risks of adverse events. We compared a new 0.8-L PEG-ascorbic acid solution containing simethicone to a 2-L PEG-ascorbic acid solution.
Methods:
In this prospective, investigator-blinded study, 137 outpatients from five centers were randomized into three groups: Group A (0.8-L PEG-ascorbic acid with a split-dose regimen), Group B (0.8-L PEG-ascorbic acid on the same day as the colonoscopy), and Group C (2-L PEG-ascorbic acid with a split-dose regimen). The primary outcome was the cleansing efficacy, assessed using the Harefield Cleansing Scale (HCS). Secondary outcomes included bubble score, polyp and adenoma detection rates, patient satisfaction, tolerability, and safety.
Results:
All groups achieved 100% successful preparation (HCS grades A and B). Group B had a higher HCS grade in the ascending colon than Group C (3.2 vs. 3.0, p = 0.01). Groups A and B showed better bubble scores than Group C (p < 0.0001). Polyp and adenoma detection rates were similar across the groups. Group B demonstrated the highest satisfaction score (139.1 ± 76.7), followed by Group A (129.8 ± 64.9) and Group C (125.6 ± 60.0), with no significant differences. The tolerability and safety parameters were similar between the groups.
Conclusions:
The novel 0.8-L PEG-ascorbic acid solution was effective, safe, and highly tolerable, showing noninferiority to the 2-L PEG-ascorbic acid solution. The same-day regimen showed a tendency toward better cleansing efficacy in the ascending colon and higher patient satisfaction.
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Polyprotic Acids