Objective:
This study investigated the intratubular decontamination promoted by high-power sonic and ultrasonic devices using either a stepwise intraoperative activation (SIA) technique or a final conventional activation (CA) approach during root canal chemomechanical preparation.
Methods:
Fifty human lower premolars were contaminated with Enterococcus faecalis and assigned into five groups (n=8): conventional syringe irrigation (CSI); final ultrasonic activation (FUA) using the ultrasonic insert 25/25 IRRI S; final sonic agitation (FSA) using the high-power sonic insert 20/28 Eddy system (both CA techniques); stepwise ultrasonic activation (SUA); and stepwise sonic agitation (SSA) using the same devices during and after canal preparation (SIA techniques). Remaining specimens served as controls. Root canal preparation was performed with the Reciproc system and 5.25% NaOCl, followed by final irrigation with 17% EDTA. Bacterial viability was assessed via confocal microscopy with Live/Dead technique. Statistical analysis was employed using non-parametric tests (α=0.05).
Results:
SUA showed the lowest bacterial viability, followed by FSA, both statistically similar. SSA and FUA were similar but less effective than SUA and FSA (p<0.05). The CSI group had significantly higher bacterial viability compared to all other groups (p<0.05).
Conclusion:
High-power sonic agitation and ultrasonic activation enhanced intratubular decontamination against E. faecalis. The SIA technique, using IRRI S or Eddy systems, effectively reduced bacterial viability and represents a promising approach for root canal disinfection. (EEJ-2024-11-185).
More Related Videos
09:02A Method to Test the Efficacy of Handwashing for the Removal of Emerging Infectious Pathogens
Published on: June 7, 2017
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
Related Concept Videos
Antimicrobial Effectiveness
Chemical Agents for Microbial Control
Hand hygiene
Hand washing...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...