Circulating tumour DNA to augment PET-CT in determining clinical outcome after head and neck cancer treatment
Sumrit Bola1, Anthony Cutts2, Dimitris Vavoulis3
1Oxford University Hospitals NHS Foundation Trust, Oxford, UK; Nuffield Department of Medicine, University of Oxford, Oxford, UK.
Aim:
PET-CT and MRI are used to assess disease response after head and neck cancer treatment. Equivocal findings can delay the potential for salvage curative treatment or result in over- treatment with further surgery. The aims of this study were to establish if liquid biopsy (LB) of circulating tumour DNA, could be used to aid decision-making after treatment.
Method:
Patients (n = 41) undergoing chemoradiotherapy (CRT) and surgical treatment had serial blood testing; pre-treatment and 10-12 weeks post-treatment, alongside imaging. PET-CT/MRIs were categorised as Cancer, Equivocal or Complete Response and true disease status was determined retrospectively. A bespoke 17-gene panel and probes targeting 5 HPV subtypes were used for next-generation sequencing in the ctDNA assay.
Results:
PET-CT was equivocal in 13/27 CRT patients; sensitivity and specificity for determining true disease status was 67 % and 42 % respectively. LB performed better at determining true disease status than PET-CT post-treatment in CRT patients; sensitivity and specificity of 83 % and 95 % respectively. A combined LB/PET/MRI test performed better than imaging alone; sensitivity and specificity of 100 % and 90 % respectively. The improved specificity was statistically significant (Fisher's exact test OR=7.1; 95 % CI:1.6-45.8, p = 0.0005), as was the balanced accuracy (Welch's t-test, p < 0.0001).
Conclusion:
LB outperformed PET-CT at determining true disease status after CRT and could complement post-treatment imaging in CRT and surgical patients, playing a potential role in decision-making after treatment.
More Related Videos
10:29Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence
Published on: August 14, 2019
10:27Testing Targeted Therapies in Cancer using Structural DNA Alteration Analysis and Patient-Derived Xenografts
Published on: July 25, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET