Related Experiment Video
Updated: Sep 14, 2025

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Anaesthetic Management of Critical Tracheal Obstruction Secondary to Granulation Tissue in a Patient With an In Situ
Chooi Lin Koh1, Sandy Lim1, Andy Jian Kai Chua2
1Department of Anaesthesiology, Sengkang General Hospital, Singapore, SGP.
Abstract:
Tracheal stenosis is a rare condition that poses significant challenges in airway management. We report a case of failed emergency awake fiberoptic intubation necessitating difficult front-of-neck access in a patient with respiratory failure, tracheal stenosis, and an in situ tracheal stent. The patient presented to the emergency department with acute respiratory distress and was urgently transferred to the operating theatre for emergent intubation. An awake intubation technique was attempted; however, the patient deteriorated during airway topicalization, necessitating rescue airway maneuvers. Bag-valve-mask ventilation proved difficult, and an attempt to insert a Portex™ size 6 endotracheal tube (Smiths Medical, Minneapolis, MN, USA) was unsuccessful due to resistance encountered after passing the vocal cords. An emergent tracheostomy was performed, but was complicated by the presence of the tracheal stent. Ultimately, a Shiley™ cuffless size 4 tube (Medtronic, Mansfield, MA, USA) was successfully inserted. Bronchoscopic assessment revealed granulation tissue both proximal and distal to the tracheal stent, with near-complete obstruction of the left main bronchus, accounting for the intubation resistance and ventilatory difficulties. The silicone tracheal stent remained in place with no signs of migration post-intubation. This case underscores the complexities of airway management in critical tracheal stenosis secondary to granulation tissue with an in situ tracheal stent.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...