A Programmable Gain Calibration Method to Mitigate Skin Tone Bias in PPG Sensors
Connor MacIsaac1, Macros Nguyen1, Alexander Uy1
1Department of Electrical Engineering, California State University Long Beach, Long Beach, CA 90803, USA.
None:
Photoplethysmography (PPG) is a widely adopted optical technique for cardiovascular monitoring, but its accuracy is often compromised by skin pigmentation, which attenuates the signal in individuals with darker skin tones. This research addresses the challenge of skin pigmentation by developing a PPG sensor system with a novel gain calibration strategy. We present a hardware prototype integrating a programmable gain amplifier (PGA), specifically the OPA3S328 operational amplifier, controlled by a microcontroller. The system performs a one-time gain adjustment at initialization based on the user's skin tone, which is quantified using RGB image analysis. This "set-and-hold" approach normalizes the signal amplitude across various skin tones while effectively preserving the native morphology of the PPG waveform, which is essential for advanced cardiovascular diagnostics. Experimental validation with over 70 human volunteers demonstrated the PGA's ability to apply calibrated gain levels, derived from a first-degree polynomial relationship between skin pigmentation and red light absorption. This approach significantly improved signal consistency across different skin tones. The findings highlight the efficacy of pre-measurement gain correction for achieving reliable PPG sensing in diverse populations and lay the groundwork for future optimization of PPG sensor designs to improve reliability in wearable health monitoring devices.
Related Concept Videos
PI Controller: Design
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Biasing of P-N Junction
In equilibrium, no external voltage is applied across the p-n junction. The depletion region is formed at the junction interface due to the diffusion of carriers, which leaves behind charged dopants, acceptors on the p-side, and donors on the n-side. These immobile charges create an electric field that prevents further diffusion of carriers. The related energy band...