Full complex amplitude control of second-harmonic generation via electrically tunable intersubband polaritonic

Jaeyeon Yu1,2, Jaesung Kim1, Hyeongju Chung1

  • 1Department of Electrical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea.

Science Advances
|July 25, 2025
PubMed

Related Concept Videos

Second-Order Circuits01:17

Second-Order Circuits

Integrating two fundamental energy storage elements in electrical circuits results in second-order circuits, encompassing RLC circuits and circuits with dual capacitors or inductors (RC and RL circuits). Second-order circuits are identified by second-order differential equations that link input and output signals.
Input signals typically originate from voltage or current sources, with the output often representing voltage across the capacitor and/or current through the inductor. For example, in...
Second-order Op Amp Circuits01:19

Second-order Op Amp Circuits

Implementing second-order low-pass filters in audio systems is crucial in refining audio signals by eliminating undesirable high-frequency noise. These filters typically involve second-order op-amp circuits configured as voltage followers, encompassing two nodes with distinct storage elements.
The analysis of such circuits follows a systematic approach, similar to the second-order RLC circuits. In practical scenarios, bulky inductors are rarely employed due to their size and weight. This means...
Voltage Doubler Circuit01:23

Voltage Doubler Circuit

A voltage doubler circuit integrates two main components: a clamping section and a rectifier section. The clamping section consists of a capacitor (C1) and a diode (D1), whereas the rectifier section is equipped with another diode (D2) and capacitor (C2). This circuit produces an output voltage with twice the amplitude of the sinusoidal input voltage.
Second Order systems I01:20

Second Order systems I

A servo system exemplifies a second-order system, featuring a proportional controller and load elements that ensure the output position aligns with the input position. The relationship between these components is described by a second-order differential equation. Applying the Laplace transform under zero initial conditions yields the transfer function, showing how inputs are converted to outputs in the system.
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Second Order systems II01:18

Second Order systems II

In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
If  ζ...
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...