Analysis of the mixed secondary radiation field in proton therapy using a Timepix detector
Andrea Nicole Matamoros Ortega1,2, Racell Nabha1,2,3, Marijke De Saint-Hubert1
1Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Center (SCK CEN), Mol, Belgium.
Abstract:
Objective.One major advantage of proton therapy (PT) over conventional photon radiotherapy is reduced dose delivered to normal tissue. However, the complexity of the secondary radiation field composed of a mixture of particles with a wide energy range makes its characterization a challenging task.Approach.Measurements with a miniaturized Timepix detector were carried out in three positions out-of-field (7.4 cm, 14.1 cm, and 18.5 cm from the isocenter), inside a phantom resembling a 5 year old undergoing proton pencil beam scanning treatment for a brain tumor. Total and particle-specific deposited energy, absorbed dose, and dose equivalent in water were calculated. Results were compared with thermoluminescent detectors (TLDs) measurements and Monte Carlo (MC) simulations modelling the experimental setup.Main results.The proton absorbed dose in water normalized to the target dose, ranged from 4.8 mGy Gy-1to 65.5µGy Gy-1, while the gamma dose, which remained consistently lower, ranged between 88.4µGy Gy-1and 6.1µGy Gy-1. The measured dose equivalent varied between 6.3 mSv Gy-1and 82.3µSv Gy-1. Good agreement was observed for the two farthest-locations when comparing the absorbed dose in water estimated by the MiniPIX Timepix detector with TLD measurements and MC simulations. However, the closest position showed an overestimation for both the absorbed dose and the dose equivalent, while the farthest position exhibited an underestimation for the dose equivalent.Significance.Out-of-field dosimetry in PT is challenging due to the complexity of the secondary mixed radiation field. Multiple detectors are typically required, but many are too large for use in anthropomorphic phantoms. This study demonstrates that the MiniPIX Timepix detector can accurately determine absorbed dose, dose equivalent and particle-specific contributions (electrons/gammas, protons, and ions). Unlike passive detectors such as TLDs, it enables active measurements with high time resolution, allowing dose rates analysis. The results, validated through experimental data and MC simulations, support the detector's potential for reliable out-of-field dose assessment and improved patient safety.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET