Research on active disturbance rejection control algorithm for pressure pulse fatigue test bench of automotive
Hongjun Meng1, Chengyu Li1, Zijing Liu2
1School of Automation and Software, Shanxi University, Taiyuan, Shanxi 030006, China.
Abstract:
When evaluating the fatigue resistance performance of automotive radiators using a pressure pulse fatigue test bench, it is necessary to periodically apply pressure signals to the radiators. The failure of any radiator during testing will induce variations in system parameters such as pressure and temperature, thereby compromising the assessment accuracy of the test platform. To address this challenge, this study proposes an active disturbance rejection control (ADRC) algorithm specifically designed for this testing system. Firstly, a mathematical model of the hydraulic system is established. Secondly, a reduced-order model-based ADRC algorithm is developed through theoretical derivation. In addition, experimental validation is conducted on the actual pressure pulse test bench. Experimental results demonstrate that, under variations in the command signal, the ADRC algorithm consistently exhibits superior pressure tracking performance and robustness compared to both conventional PID and fuzzy PID control algorithms.
More Related Videos
Related Concept Videos
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...