Background:
Our study aimed to assess the effects of inhaled nitric oxide (iNO) on ventilation/perfusion mismatch, and individual variability in patients with acute respiratory distress syndrome (ARDS) by electrical impedance tomography (EIT).
Methods:
This single-center, prospective physiological study enrolled mechanically ventilated ARDS patients. All patients initially received 5 ppm iNO; responders (≥ 20% increase in PaO2/FiO2 at 30 min) maintained this dose, while non-responders had their dose doubled every 30 min, up to 40 ppm, until achieving a ≥ 20% improvement. The trial lasted 3 h. EIT data and clinical respiratory and hemodynamic parameters were collected at baseline (0 h), and at 30 min and 3 h after iNO initiation.
Results:
At 30 min, 36.7% (11/30) of patients responded, associated with younger age and lower prevalence of hypertension. Among responders, the proportion of ventral perfusion significantly increased at 3 h, with this change already observed at 30 min. Responders also showed a significant reduction in the proportion of only perfused units in the dorsal region at 30 min; at the whole-lung level, the proportions of only perfused units and unmatched units decreased. In contrast, non-responders showed an increased proportion of only perfused units in both the dorsal region and whole lung at 3 h compared to baseline, following prolonged high-dose iNO administration.
Conclusions:
The response to iNO varied. In responders, EIT showed a potential redistribution of lung perfusion toward ventral regions, with reductions in the proportions of only perfused units and unmatched units in the whole lung.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: