Related Experiment Video
Updated: Sep 13, 2025

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Clinical evaluation of tissue-dependent and spatially-variant positron range correction for Gallium-68 PET imaging
Prodromos Gavriilidis1,2,3, Michel Koole3, Felix M Mottaghy1,4
1Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.
Purpose:
Positron range correction (PRC) can mitigate the effect of the larger positron range on the image quality of Gallium-68 (68Ga) PET-imaging. The aim of this study is to evaluate the improvement in 68Ga-PET image quality by applying a tissue-dependent and spatially-variant PRC (TDSV PRC) for 68Ga in a clinical setting.
Methods:
A TDSV PRC technique was developed employing CT-driven segmentation masks of different tissue types (soft tissue, bone, lung) and the corresponding tissue-specific positron range kernels. OSEM reconstructions were performed using the proposed TDSV PRC, a tissue-independent PRC, and without any PRC (non-PRC). For lesions identified in [68Ga]Ga-DOTATOC or [68Ga]Ga-PSMA PET/CT data from 20 patients, the maximum standardized uptake value (SUVmax) and contrast-to-noise ratio (CNR) of this technique was compared to tissue-independent PRC and non-PRC images.
Results:
A total of 93 lesions were analyzed (48 soft tissue, 35 bone, 10 lung lesions). For soft tissue lesions, TDSV and tissue-independent PRC showed similar increases in SUVmax (13.7%, p < 0.001 vs. 13.6%, p < 0.001) and CNR (11.0%, p < 0.001 vs. 11.1%, p < 0.001) compared to non-PRC. For bone lesions, tissue-independent PRC showed slightly higher not statistically significant increases than TDSV PRC in SUVmax (18.6%, p < 0.001 vs. 17.4%, p < 0.001) and CNR (14.6%, p < 0.001 vs. 13.8%, p < 0.001). In lung lesions, TDSV PRC increased SUVmax and CNR compared to non-PRC (SUVmax: 57.9%, p = 0.012; CNR: 43.9%, p = 0.012) and tissue-independent PRC (SUVmax: 46.0%, p = 0.012; CNR: 32.5%, p = 0.012).
Conclusion:
TDSV PRC for 68Ga PET/CT demonstrated to be feasible in clinical patient data, showing the greatest benefits for lung lesions.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...