Related Experiment Video
Updated: Sep 13, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Time Required for Extubation While Using Bispectral Index Monitoring Compared to End-Tidal Anesthetic Gas
Amithkumar Sk1, Deepak V Kadlimatti1, Santosh Kumar1
1Department of Anaesthesiology, Dr. B.R. Ambedkar Medical College & Hospital, Bengaluru, IND.
Objective:
The objective of this study was to compare extubation timings between patients monitored with the bispectral index (BIS) and those monitored using end-tidal anesthetic gas (ETAG) to determine which method provides a more efficient recovery profile.
Methodology:
A prospective observational study was conducted on 50 patients aged 18 to 60 years, classified as American Society of Anesthesiologists (ASA) physical status I-II, undergoing elective surgeries under general anesthesia (GA). Patients were randomized into BIS and non-BIS (ETAG) groups to assess anesthetic consumption and recovery characteristics. Standard anesthetic protocols were followed. In the BIS group, BIS values were maintained between 40 and 60, while in the ETAG group, end-tidal isoflurane concentrations were kept between 0.7 and 1.3 minimum alveolar concentration (MAC). Intraoperative parameters and extubation times were recorded. Isoflurane administration was discontinued at the time of skin closure, and neuromuscular blockade was reversed once a train-of-four (TOF) ratio greater than 0.9 was confirmed. Data were analyzed using SPSS version 26.0 (IBM Corp., Armonk, NY), with a p-value less than 0.05 considered statistically significant.
Results:
There was no statistically significant difference in the overall duration of anesthesia between the two groups (p > 0.05). However, the BIS group had a significantly shorter extubation time, averaging 148.4 ± 30.5 seconds, compared to 201.2 ± 43.6 seconds in the ETAG group. The mean difference was 52.8 ± 13.1 seconds (p = 0.001). Additionally, the average hourly isoflurane consumption was significantly lower in the BIS group (5.9 ± 0.77 mL) compared to the ETAG group (6.56 ± 1.12 mL), with a mean difference of 0.66 ± 1.04 mL (p = 0.01).
Conclusion:
Extubation occurred significantly earlier in patients monitored with BIS than in those observed with ETAG. Furthermore, BIS-guided anesthesia was associated with reduced isoflurane consumption compared to ETAG-guided monitoring.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
08:49Assessing Changes in Volatile General Anesthetic Sensitivity of Mice after Local or Systemic Pharmacological Intervention
Published on: October 16, 2013
Related Concept Videos
Stages of General Anesthesia
Inhalational Anesthetics: Overview
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...