Related Experiment Video
Updated: Sep 13, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Nonlinear response analysis of plan and vertical asymmetric reinforced concrete buildings under directional seismic
Pramod Kumar1, Seeram Madhuri1, Bamidele Charles Olaiya2
1Department of Civil Engineering, National Institute of Technology, Jamshedpur, Jharkhand, 831013, India.
Abstract:
A nonlinear dynamic analysis is conducted on plan and vertically asymmetric reinforced concrete buildings subjected to directional seismic forces. The mathematical models are developed for building models. The plan asymmetry in the building is introduced by imposing uniaxial eccentricities of 6 m, 12 m, and 18 m. The vertical mass and stiffness asymmetry at different building levels is introduced by varying the mass or stiffness in the vertical direction. The peak displacement and the inter-storey drift ratio are evaluated. The vulnerability of asymmetric buildings to earthquake forces increases up to a specific eccentricity. Compared to stiffness and mass asymmetric buildings, stiffness asymmetry at the bottom floor and mass asymmetry at the top floor have shown a larger response in all the earthquakes and angles of study. The peak responses for plan and vertically symmetric buildings are observed under unidirectional earthquake forces. The peak displacement is 80 mm in the Y direction for the plan asymmetric structures. The vertical stiffness of asymmetric structures showed a peak response of 300 mm in the Y direction. The building with mass asymmetry at the top showed 199.18 mm in the Y direction. The authors recommend a detailed analysis of the design and analysis of asymmetric structures, especially to predict material failure.
Related Concept Videos
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Eccentric Axial Loading in a Plane of Symmetry
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Elastic Curve from the Load Distribution
For all beams, the analysis of the beam's reaction to distributed loads begins by understanding the relationship between a beam's load and the resulting shear forces and bending moments.
Plastic Deformations of Members with a Single Plane of Symmetry