Related Experiment Video
Updated: Sep 13, 2025

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
The Implementation and Application of a Saudi Voxel-Based Anthropomorphic Phantom in OpenMC for Radiological Imaging
1Department of Radiological Science, College of Applied Medical Sciences, Imam Abdulrahman bin Faisal University, P.O. Box 2435, Dammam 31441, Saudi Arabia.
None:
Objectives: This study aimed to implement a high-resolution Saudi voxel-based anthropomorphic phantom in the OpenMC Monte Carlo (MC) simulation framework. The objective was to evaluate its applicability in radiological simulations, including radiographic imaging and effective dose calculations, tailored to the Saudi population. Methods: A voxel phantom comprising 30 segmented organs/tissues and over 32 million voxels were constructed from full-body computed tomography data and integrated into OpenMC. The implementation involved detailed voxel mapping, material definition using ICRP/ICRU-116 recommendations, and lattice geometry construction. The simulations included X-ray radiography projections using mesh tallies and anterior-posterior effective dose calculations across 20 photon energies (10 keV-1 MeV). The absorbed dose was calculated using OpenMC's heating tally and converted to an effective dose using tissue weighting factors. Results: The phantom was successfully modeled and visualized in OpenMC, demonstrating accurate anatomical representation. Radiographic projections showed optimal contrast at 70 keV. The effective dose values for 29 organs were calculated and compared with MCNPX, the ICRP-116 reference phantom, and XGBoost-based machine learning (ML) predictions. OpenMC results showed good agreement, with maximum deviations of -35.5% against ICRP-116 at 10 keV. Root mean square error (RMSE) comparisons confirmed reasonable alignment, with OpenMC displaying higher RMSEs relative to other methods due to expanded organ modeling and material definitions. Conclusions: The integration of the Saudi voxel phantom into OpenMC demonstrates its utility for high-resolution dosimetry and radiographic simulations. OpenMC's Python (version 3.10.14) interface and open-source nature make it a promising tool for radiological research. Future work will focus on combining MC and ML approaches for enhanced predictive dosimetry.
More Related Videos
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET