Related Experiment Video
Updated: Sep 13, 2025

Optimization of a Multiplex RNA-based Expression Assay Using Breast Cancer Archival Material
Published on: August 1, 2018
The Prognostic Value of High-Sensitive Troponin T Rise Within the Upper Reference Limit in Breast Cancer: A
Sergey Kozhukhov1,2, Nataliia Dovganych1,2
1SI NSC The M.D. Strazhesko Institute of Cardiology, Clinical and Regenerative Medicine of the National Academy of Medical Sciences of Ukraine, 03680 Kyiv, Ukraine.
Abstract:
Background: We investigated the role of a high-sensitive cardiac troponin T (hsTnT) increase below the upper limit of normal (ULN) in patients with breast cancer (BC). hsTnT assays accurately quantify very low plasma troponin concentrations and enable the early detection of cardiomyocyte injury before a drop in the left ventricular ejection fraction (LVEF). The increase in hsTnT below the ULN in response to chemotherapy has not previously been studied. Method: This was an open-label pilot study. Female patients with newly diagnosed BC scheduled to receive systemic cancer treatment were recruited. Blood sampling and echocardiography were performed at baseline, at 3 and 6 months of cancer treatment. hsTnT concentrations were measured using the Elecsys TnT hs assay (Roche Diagnostics). The limit of blank and 99th percentile cutoff values for the hsTnT assay were 3 and 14 ng/L. We calculated the rise in hsTnT (ΔhsTnT) by the difference (%) between its baseline level and during follow-up (FU) in each patient. Results: Among eligible subjects, we excluded 4 patients before the start of treatment and 17 patients during the follow-up with values for the hsTnT >14 ng/L. Finally, 60 women with a median age of 48.6 ± 1.3 years were included in the study. The median baseline hsTnT concentration was 5.5 ± 1.4 ng/L. During 6 months of cancer treatment, hsTnT increased in all patients by up to 10-305% from baseline, with an average of 94.2%. LV EF was normal at baseline and decreased significantly compared to the value before cancer treatment (61.9 ± 3.3% vs. 56.3 ± 7.0%; p < 0.045). We correlated the hsTnT rise with a drop in LV EF ≥ 10% from its baseline level. Logistic regression analysis showed that Δ hsTnT has a good predictive value for LV dysfunction, 0.78 (p = 0.05), 95% CI (0.67-0.90). The increase in hsTnT > 81% was determined as the optimal threshold value for detecting early biochemical cardiotoxicity. Conclusion: It was investigated that hsTnT rise within the cutoff < 14 ng/L can be used as a marker of early biochemical cardiotoxicity and is valuable for predicting LV drop in 6 months of FU. We conclude that BC patients with increased hsTnT plasma concentration > 81% from the baseline value should be considered as high-risk patients for cardiotoxicity and need more precise cardiac monitoring and early preventive medical intervention strategies.
More Related Videos
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
11:34Building Up a High-throughput Screening Platform to Assess the Heterogeneity of HER2 Gene Amplification in Breast Cancers
Published on: December 5, 2017
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
mTOR Signaling and Cancer Progression
The mTOR pathway or the...