Evaluation of Ear Thermographic Imaging as a Potential Variable for Detecting Hypocalcemia in Postpartum Holstein

Guilherme Violin1, Nanako Mochizuki1, Simon Stephen Abraham Warju1

  • 1Department of Veterinary Medicine, Obihiro University of Agriculture and Veterinary Medicine, Obihiro 080-8555, Hokkaido, Japan.

Hypocalcemia is common in dairy cows within the first 72 h post-calving, and can be either clinical or subclinical. Early detection is critical, but traditional laboratory tests are time-consuming and cow-side tests remain costly. A classic symptom of hypocalcemia is reduced ear skin temperature, which has been explored as a diagnostic tool in a previous study, but was not recommended at the end. Additionally, ambient temperature was found to strongly influence ear skin temperature, complicating diagnosis. The present study investigates infrared thermography of the ear as a potential non-invasive method for helping in the detection of hypocalcemia in Holstein cows. In order to differ from the previous study, with the goal of improving diagnosis accuracy, this research analyzed the entire ear temperature using infrared imaging software. Ambient temperature was factored in by categorizing samples into two groups based on air temperature: colder (-1.6 to 14.6 °C) and hotter (15.3 to 31.2 °C). Forty-two cows were monitored during the perinatal period, with blood samples and thermographic images taken twice a day until 48 h after calving. This study found that the median surface temperature of the ear correlated strongly with environmental temperature (r = 0.806, p < 0.001) and weakly with blood ionized calcium levels (r = 0.310, p < 0.01). In colder air temperatures, ear surface temperature was significantly different between healthy and hypocalcemic cows (p = 0.014). Logistic regression models were used to assess ionized calcium status based on different combinations of ear surface temperature, its difference from air temperature, and days in milk. In hotter air temperatures, only ear surface temperature, with no other covariates, was able to generate a valid model (p = 0.029). In colder air temperatures, multiple combinations of those variables generated valid models (p < 0.05), with the difference between ear and air temperature, together with days in milk, performing the best. Thus, this study concluded that ear surface temperature obtained through infrared thermography, while not promising for warmer environments, does show application potential for helping in the detection of hypocalcemia in colder environments.

Related Concept Videos

Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
2.2K
Assessing Body Temperature - Tympanic membrane01:14

Assessing Body Temperature - Tympanic membrane

Assessing tympanic membrane temperature involves using a tympanic membrane thermometer (TMT). Here is a step-by-step guide:
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
669
Assessing Body Temperature - Rectal01:27

Assessing Body Temperature - Rectal

Rectal temperature measurement is considered the most precise method for assessing core body temperature and typically registers higher than oral temperature. For adults, the rectal thermometer should be inserted 1 to 1.5 inches into the rectum to obtain the most accurate reading.
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
6.5K
Assessing Body Temperature - Temporal Artery01:19

Assessing Body Temperature - Temporal Artery

Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.  
Step 3: Assess the patient's...
672
Assessing Body Temperature - Oral01:14

Assessing Body Temperature - Oral

Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
837
Assessing Body Temperature - Axilla01:14

Assessing Body Temperature - Axilla

Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
663