The Effect of Assistive Devices on the Accuracy of Fitbits in Healthy Individuals: A Brief Report
John Jaworski1, Brian Makowski1, Michael Weaver1
1Department of Physical Therapy, Daemen University, Amherst, NY 14226, USA.
Abstract:
Our study explored the accuracy of Fitbit recorded step count during the use of an assistive device (two-wheeled walker and standard cane) at various body positions (wrists, hips, and ankles). Participants (n = 11) ambulated an obstacle course (50 m total, including turns and a step up/down) a total of three times (two-wheeled walker, standard cane, and a deviceless control trial). Fitbit generated step counts (at the wrists, hips, and ankles) were then compared to the individual's "actual" step count captured through video analysis. During the cane trial and the deviceless trial, all positions were significantly correlated (r = 0.764 to 0.984; p < 0.006) with the actual step count. However, increased variability (demonstrated by increased limits of agreement) was observed when the Fitbit was worn on the wrist (compared to the hips or ankles). During the walker trial, the step count was significantly correlated to the actual step count at the ankle and hip positions (r = 0.669 to 0.888; p < 0.017) with an average error of 1.5%, while it was not statistically correlated at the wrist with a 31.2% average error. Our study suggests that Fitbits are a good predictor of actual step count, with the caveat that the location of the Fitbit should be considered if an assistive device (e.g., two-wheeled rolling walker and single-point cane) is being used.
More Related Videos
15:00Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Holter Monitor: 24-Hour Monitoring