Superiority of black-blood computed tomography over conventional computed tomography angiography in the identification of soft plaques: a prospective study
Related Experiment Video
Updated: Sep 13, 2025

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Tao Zhou1, Ying Li1, Nannan Sun1
1Department of Radiology, People's Hospital Affiliated to Shandong First Medical University, Jinan, China.
Background:
Carotid computed tomography angiography (CTA) has limited diagnostic value in evaluating the vulnerability of soft plaques. This study compared conventional CTA and black-blood computed tomography (BBCT) in terms of image quality and the ability to diagnose carotid soft plaques.
Methods:
Patients who underwent carotid CTA and magnetic resonance (MR) vessel wall examination were included in this prospective study. The image quality of plaques was evaluated through objective evaluation [CT values, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) based on CTA and BBCT] and subjective evaluation. Plaque burden was assessed with the normalized wall index (NWI) in CTA, BBCT, and MR images, as was the remodeling index (RI). The number of soft plaques in CTA, BBCT, and MR images was recorded. The sensitivity, specificity, and accuracy of an NWI higher than 0.56 and an RI higher than 1.0 from CTA and BBCT images in assessing the vulnerability of soft plaques were calculated with MR vessel wall images as a reference standard.
Results:
A total of 37 patients comprising 53 soft plaques (25 males and 12 females) were analyzed. The average CT values, SNR, and CNR of soft plaques in BBCT were significantly higher compared to those in CTA (BBCT: 65.38±21.34, 16.31±7.69, 6.47±4.97; CTA: 45.58±14.09, 7.16±3.15, 4.45±2.83; all P values <0.05). The image noise in BBCT was significantly lower than that in CTA (BBCT: 10.73±3.75; CTA: 15.52±6.59; P<0.05), while the subjective image score of BBCT (3.04±0.51) was significantly higher than that of CTA (2.32±0.61) (P<0.001). The sensitivity and specificity of an NWI higher than 0.56 with BBCT were 0.98 and 0.86, respectively, which were superior to those with CTA at 0.83 and 0.57, respectively. Meanwhile, the sensitivity and specificity of an RI higher than 1.0 with BBCT were 0.86 and 0.95, respectively, which were superior to those with CTA at 0.71 and 0.85, respectively. The sensitivity and specificity of BBCT in diagnosing vulnerable plaques were 0.90 and 0.93, respectively, while those of CTA were 0.62 and 0.79, respectively. The area under the receiver operating characteristic curve of BBCT for diagnosing vulnerable plaques was 0.91 (95% CI: 0.803-0.973) while that for CTA was 0.70 (95% CI: 0.559-0.819; P<0.001).
Conclusions:
Compared to conventional CTA, BBCT provides improved image quality and diagnostic performance in assessing carotid soft plaques.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI