Related Experiment Video
Updated: Jun 25, 2026

10:20
Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
16.1K
A Validated RP-HPLC Method for Monitoring Pollutants Removal during Microalgae Bioremediation of Polluted Waters.
Bruna Santos1,2,3, Juliana Araújo4, Filomena Freitas1,2
1i4HB - Institute for Health and Bioeconomy, School of Science and Technology, NOVA University Lisbon, 2829-516, Caparica, Portugal.
Bulletin of Environmental Contamination and Toxicology
|July 29, 2025
Summary
A new Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) method accurately quantifies six contaminants of emerging concern (CECs) during microalgae bioremediation. This validated technique supports environmental monitoring and the assessment of microalgae
Area of Science:
- Analytical Chemistry
- Environmental Science
- Biotechnology
Background:
- Contaminants of emerging concern (CECs) pose risks to aquatic ecosystems.
- Microalgae bioremediation is a promising approach for removing CECs.
- Accurate quantification methods are essential for evaluating bioremediation efficacy.
Purpose of the Study:
- To develop and validate a simultaneous RP-HPLC method for quantifying six specific CECs.
- To assess the method's performance for microalgae bioremediation studies.
- To demonstrate the method's applicability in real-world environmental samples.
Main Methods:
- Reversed-Phase High-Performance Liquid Chromatography (RP-HPLC) was employed.
- Method validation followed standard guidelines, assessing linearity, accuracy, precision, and recovery.
- Limits of detection (LOD) and quantification (LOQ) were determined for each CEC.
Main Results:
- The RP-HPLC method demonstrated linearity, accuracy, and precision within acceptable limits.
- LODs ranged from 0.008 µg mL⁻¹ (imidacloprid) to 0.024 µg mL⁻¹ (methylparaben).
- High percentage recovery (80-120%) was achieved for most CECs, with triclosan showing lower recovery due to solubility issues.
Conclusions:
- The validated RP-HPLC method is suitable for the simultaneous quantification of six CECs.
- The method is effective for monitoring CEC removal during microalgae bioremediation.
- This analytical tool aids in assessing the efficiency of microalgae in environmental cleanup.