Related Experiment Video
Updated: Sep 13, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Does Combining a Mobile Dose Calculation App with a Continuous Insulin Infusion System Improve Glycemic Control and
Pedro Pujante Alarcón1, Elías Delgado Álvarez1, Carmen Lambert Goitia1
1Hospital Universitario Central de Asturias (HUCA), Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain.
None:
Introduction: Achieving optimal glycemic control in patients with type 1 diabetes mellitus (PwT1DM) is essential to prevent complications. Continuous subcutaneous insulin infusion (CSII) systems combined with continuous glucose monitoring (CGM) have improved outcomes, but the effectiveness of additional technologies, such as mobile apps and hybrid closed-loop systems (HCLSs), remains unclear. This study evaluates glycemic control and quality of life (QoL) in adult PwT1DM transitioning from multiple daily injections (MDI) to a CSII, first with the Mylife™ Dose app and subsequently switching to an HCLS. Materials and Methods: This was a 10-month, multicenter, open-label sequential study involving 135 adults with type 1 diabetes (T1D), all of whom were using isCGM and MDI before transitioning to CSII, first with the Mylife Dose app and later to an HCLS. Glycemic control (glycated hemoglobin [HbA1c], time in range [TIR], time below range, time above range), insulin requirements, and QoL/treatment satisfaction/hypoglycemia perception (Diabetes Quality of Life questionnaire, Diabetes Treatment Satisfaction Questionnaire, Clarke's test) were measured at each of the four study visits. Results: Transitioning from MDI to CSII showed modest improvements in HbA1c (7.57%-7.42%; P = 0.02) and TIR (56.3%-60.4%; P < 0.01). The introduction of the Mylife Dose app did not provide significant additional improvements in glycemic control or QoL, although it provided an additional tool for diabetes management. However, switching to an HCLS resulted in substantial improvements in HbA1c (6.7%), TIR (73.1%), and QoL, with over 70% of patients achieving an HbA1c <7%. Insulin requirements increased slightly with the HCLS, primarily due to basal insulin. Adherence was high, with 88.1% completing the study. Conclusions: The Mylife Dose app does not improve glycemic control or QoL significantly but offers convenience for patients with T1D. In contrast, HCLSs provide significant metabolic and QoL benefits, supporting their integration into T1D management with appropriate reimbursement policies.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...

