Real-time motion modeling and treatment verification for irregular motion in carbon ion therapy: a feasibility study
Cosimo Galeone1,2,3, Anestis Nakas4, Marco Donetti5
1Biophysics, GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Darmstadt, Germany.
Abstract:
Objective.Irregular motion impacts treatment accuracy and can be compensated by larger margins or online adaptive approaches. A seamless workflow for fast and accurate 4D-dose reconstruction allows dosimetric monitoring intra- and inter-fractionally, as a basis for adaptive therapy. This study presents a real-time, motion-adaptive framework that combines motion modeling and treatment verification, integrated into the dose delivery and monitoring systems to enable continuous assessment of the delivered 4D-dose.Approach.The framework includes a GPU-based analytical algorithm for real-time dose reconstruction in carbon ion therapy, interfaced with the dose delivery and optical tracking systems at the Centro Nazionale di Adroterapia Oncologica (CNAO). A motion model, driven by external surrogate tracking, generates a virtual CT every 150 ms, used for 4D-dose reconstruction with measured spot parameters. Planned and delivered doses are compared after each iso-energy slice. The framework was validated at CNAO using a geometric target and a 4D lung tumor phantom with a moving 2D ionization chamber array, under regular and irregular motion patterns.Main results.The framework successfully generated real-time CT images of the lung phantom, showing strong agreement with ground-truth images. Dose reconstructions were performed within inter-spill times during delivery, ensuring rapid assessment. Comparisons against detector measurements yielded an average gamma-index passing rate of 99% (3%/3 mm), confirming the accuracy of both the motion model and the integrated treatment verification system.Significance.This work presents the first real-time framework for carbon ion therapy, integrating motion modeling and dose reconstruction to handle irregular motion, fully embedded in a clinic-like setup.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...