Bridging spatiotemporal wildfire prediction and decision modeling using transformer networks and fuzzy inference
1Symbiosis Institute of Technology, Nagpur Campus, Symbiosis International (Deemed University), Pune, India.
None:
Wildfires present a growing threat to ecosystems, human settlements, and climate stability, necessitating accurate and interpreted prediction systems. Existing AI-based models often prioritize performance over explainability, limiting their utility in real-time decision-making contexts. Current wildfire forecasting models struggle to incorporate uncertainty and offer transparent response strategies. Moreover, many models fail to integrate domain knowledge in a way that supports actionable interventions. This study utilizes the Canadian Fire Spread Dataset, augmented with Sentinel, ERA5, and SRTM data, encompassing vegetation, meteorological, and topographic variables. The suggested system uses a Transformer-based model to predict fires over time and space, along with a Fuzzy Rule-Based System (FRBS) to create rules for responding to those predictions. This integration allows for both high accuracy and interpretability in decision-making under uncertain environmental conditions. The novelty lies in the use of symbolic fuzzy reasoning layered onto a deep attention-based architecture. Performance was evaluated using metrics such as accuracy, precision, recall, F1-score, and AUC. The model achieved an F1-score of 92.9 % and accuracy of 94.8 %, significantly outperforming baseline and deep learning alternatives. • Integrates deep learning with fuzzy logic for both accurate forecasting and interpretable response planning. • Enables uncertainty-aware reasoning by translating predictions into actionable fire management rules. • Demonstrates superior performance across diverse environmental datasets using multi-source satellite and climate inputs.
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Transformers with Off-Nominal Turns Ratios
Applications of GIS: Disaster Management and Emergency Response
Multi-input and Multi-variable systems
In the absence...
Survival Tree
Building a Survival Tree
Constructing a...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...

