Real-time beat-to-beat pulse wave velocity estimation: a quality-driven approach using laser Doppler vibrometry
Silvia Seoni1, Patrick Segers2, Simeon Beeckman2
1Biolab, PoliTo BIOMed Lab, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 , Turin, Italy. silvia.seoni@polito.it.
None:
Arterial stiffness, a key cardiovascular risk marker, is typically assessed via carotid-femoral pulse wave velocity (cf-PWV), the gold-standard method. In this study, we introduce CAPE (Continuous Automatic PWV Estimation), an innovative framework for near real-time cf-PWV estimation based on beat-to-beat analysis of laser-Doppler vibrometry (LDV) signals. CAPE integrates automatic fiducial point detection, systematic signal quality control, and a cross-channel strategy to provide a highly reliable assessment of cf-PWV. The framework was evaluated using LDV signals acquired from 100 patients with mild to moderate essential hypertension, using a multichannel laser vibrometry system. CAPE calculates cf-PWV as the ratio of carotid-femoral distance to pulse transit time (PTT), which is the delay between carotid and femoral fiducial points. These points are detected using template-matching on the second derivative of LDV displacement signals. Signal quality in CAPE is ensured through an integrated quality assessment based on the number of automatically detected carotid-femoral peaks, which assigns confidence scores (acceptable or excellent) to the PWV measurements. When validated against the gold-standard applanation tonometry, CAPE achieved a mean bias of 0.25 ± 0.77 m/s, demonstrating high reliability and precision. The optimized framework estimates cf-PWV in 3 s, making CAPE ideal for clinical applications requiring real-time cardiovascular assessment.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Velocity and Acceleration of a Wave
The velocity of the particles can be obtained by taking the partial derivative of the position equation with respect to time....
Special considerations while measuring pulse
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)