Related Experiment Video
Updated: Sep 13, 2025

Perceptual and Category Processing of the Uncanny Valley Hypothesis' Dimension of Human Likeness: Some Methodological Issues
Published on: June 3, 2013
Could this atypical image be an unexpected combination? A visual vignette
Ridvan Isik1, Sena Unver2, Savas Sencan3
1Sakarya Training and Research Hospital, Department of Physical Medicine and Rehabilitation, Division of Pain Medicine, Sakarya, Turkey.
This case highlights unusual contrast spread and pulsation during transforaminal epidural steroid injection (TFESI). Recognizing these atypical images is crucial for pain management physicians to prevent complications.
Area of Science:
- Interventional Pain Management
- Neuroradiology
- Spinal Procedures
Background:
- A case report detailing a patient undergoing transforaminal epidural steroid injection (TFESI).
- Observation of concurrent intradural contrast media spread and dural pulsation during the procedure.
Purpose of the Study:
- To increase awareness regarding the recognition of atypical imaging findings in interventional pain procedures.
- To emphasize the importance of understanding contrast media behavior during TFESI.
Main Methods:
- A 67-year-old female patient with lumbar spinal stenosis received L3 TFESI under C-arm fluoroscopy.
- Initial contrast distribution suggested subdural spread, followed by observation of localized, pulsatile contrast accumulation.
- Procedure was terminated, and further imaging (MRI, CT angiography) was performed.
Main Results:
- The patient experienced no neurological deficits post-procedure.
- Subsequent imaging ruled out other potential causes for the observed contrast patterns.
- Medical management was initiated for the patient's persistent pain.
Conclusions:
- Atypical contrast media distribution patterns can occur during TFESI.
- Physicians must possess comprehensive knowledge of contrast behavior to mitigate potential procedural complications.
Related Concept Videos
Unusual Results
According to the range rule of thumb, any value above or below two standard deviations, 2σ from the mean, μ is considered unusual.
Maximum unusual value =...
X-ray Imaging
Schemas
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

