Functional Human Liver Preservation and Recovery by Means of Subnormothermic Machine Perfusion
Published on: April 27, 2015
Liver Transplantation After Ex-Vivo Normothermic Machine Perfusion: A No-Recooling Technique With Room-Temperature
Salvatore Gruttadauria1,2, Ivan Vella1, Sergio Calamia1
1From the Abdominal Center Department, Istituto Mediterraneo per i Trapianti e Terapie ad alta specializzazione - IRCCS ISMETT, Palermo, Italy.
None:
Normothermic machine perfusion (NMP) has emerged as a valuable preservation technique in liver transplantation, offering improved graft assessment and viability. Traditionally, liver grafts undergo a second cooling phase before implantation, which may contribute to cellular damage through ischemia-reperfusion injury. In this "How To Do It" article, we describe our surgical technique to avoid re-cooling following NMP. Specifically, after retrieval from the perfusion device, the graft is directly inserted into the surgical field and undergoes a standardized portal flush with 1 L of 5% albumin at room temperature before reperfusion. This method maintains physiological temperature, potentially reducing reperfusion stress and enhancing graft function. We detail step-by-step procedural aspects, including organ handling, vascular anastomoses, and intraoperative considerations, supported by our clinical outcomes.