Efficient and stable electro-Fenton treatment of antibiotics-containing wastewater over NiFe bimetal atom catalyst via flow-through micro-nanoscale spatial confinement system
Related Experiment Video
Updated: Jul 9, 2026

Electrochemically and Bioelectrochemically Induced Ammonium Recovery
Published on: January 22, 2015
Danyu Zhang1, Yarong Chen2, Yuchen Wang3
1Hunan Provincial University Key Laboratory for Environmental Behavior and Control Principle of New Pollutants, College of Environment and Resources, Xiangtan University, Xiangtan 411105, PR China; College of Materials Science and Engineering, Hunan University of Science and Technology, Xiangtan 411201, PR China; State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, Changsha 410082, PR China.
Abstract:
The engineering application of electro-Fenton process is subject to limited availability of •OH caused by mass transfer limitation and the short lifetime of •OH in water. In this study, an efficient electro-Fenton treatment process is developed by constructing a flow-through micro-nanoscale spatial confinement electrode with NiFe bimetal atom catalyst for oxygen reduction reaction (ORR). The NiN4-FeN4 active sites are anchored onto carbon nanotubes grown in the tunnel of carbonized pine wood (NiFe-NCNTs-CP). Efficient generation of •OH is achieved through 3-electron ORR over NiFe-NCNTs-CP. Because of the unique flow-through micron-nanoscale confinement environment, the concentration of accumulated •OH reaches as high as 6092 μmol L-1 min-1 even though the water flux is up to 236 L m-2 h-1 (equivalent to a retention time of 60 s). The proposed electro-Fenton system achieves 100 % removal of florfenicol, thiamphenicol, chloramphenicol, sulfamethoxazole, and tetracycline in water within just 60 s (C0=20 mg L-1, pH=7, 0.7 V vs SCE). The proposed continuous flow process maintains highly stable for treating actual medical wastewater within 8 days, achieving discharge standards and eliminating the antibacterial activity of medical wastewater. Furthermore, the proposed process showed a low energy consumption of only 7.35 kWh kg (COD)-1. This study presents a highly practical electro-Fenton process for organic wastewater treatment.
More Related Videos
08:34A Dual-Functional Electroactive Filter Towards Simultaneously SbIII Oxidation and Sequestration
Published on: December 5, 2019
08:30A Complete Method for Evaluating the Performance of Photocatalysts for the Degradation of Antibiotics in Environmental Remediation
Published on: October 6, 2022
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Microbial Wastewater Treatment
Microbial Corrosion
Microbial Fuel Cells
Biological Treatment of Effluent and Waste Water