Repeated measurement of lipoprotein(a): technical versus biological variability
Adriana Koller1, Cathrin Pfurtscheller1, Azin Kheirkhah1
1Institute of Genetic Epidemiology, Medical University of Innsbruck, Innsbruck, Austria.
Background And Aims:
Repeated measurements of Lp(a) concentrations are not considered relevant since Lp(a) is expected to remain relatively stable during life through the strong genetic determination. This has recently been questioned by reports showing major fluctuations of Lp(a) over time. However, these studies have not distinguished between biological or technically caused variability. Therefore, this study aimed to assess the biological variability of Lp(a) concentrations over time while minimizing technical variability to evaluate the clinical relevance of repeated Lp(a) measurements.
Methods:
Lp(a) concentrations were measured in duplicates in 715 elderly people with two blood collections 3.2 years apart and having the sample pairs (baseline and follow-up) on the same assay plate.
Results:
The Lp(a) concentrations of sample pairs were strongly correlated (r = 0.98). We grouped individuals according to risk categories from the baseline Lp(a) measurement of <30, 30 to <50, 50 to <70 and ≥ 70 mg/dL and observed that between baseline and follow-up 655 of the 715 individuals (91.6 %) remained in their risk category, while 33 (4.6 %) moved to a higher and 27 (3.8 %) to a lower category. We calculated that each 5 mg/dL incorrectly measured Lp(a) concentration results in a 1 % miscalculation of the lifetime cardiovascular risk. This is relatively small considering that roughly a third of the population is dying from cardiovascular disease.
Conclusions:
Clinically relevant changes of Lp(a) concentrations by biological variability do not occur frequently in an elderly population. Major changes of Lp(a) as reported in the literature might be caused by technical rather than biological fluctuations and argues for repeated Lp(a) measurements in specific cases and an improvement of the quality control measures in laboratory practice.
Related Concept Videos
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Uncertainty in Measurement: Accuracy and Precision
Blood Studies for Cardiovascular System III: Serum Lipid Profile
Serum lipids are fats and fatty substances in the blood and are crucial for various bodily functions, including energy storage, cellular structure, and hormone production. Serum lipids consist of cholesterol, triglycerides, and phospholipids.
Cholesterol is a soft, fat-like substance found in all body cells. It is crucial for producing hormones, vitamin D, and substances that aid...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...