Related Experiment Video
Updated: Sep 13, 2025

Guidelines for Elective Pediatric Fiberoptic Intubation
Published on: January 17, 2011
Evaluating the Accuracy of Laryngoscopic View Documentation During Tracheal Intubation in a Pediatric Emergency
Preston Dean1,2, Maria Hooker3, Benjamin T Kerrey1,2
1Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA.
Objectives:
Review of self-reported data in the electronic medical record (EMR) is the standard approach to the study of emergency airway management. Despite this, very little research has been done into the accuracy of the laryngoscopic views documented in the EMR during intubation in the emergency department. Complicating matters further, the original Cormack-Lehane (CL) airway grading system and the newer modified CL grading system have overlapping definitions. The objective of this study was to compare the laryngoscopic views documented in the EMR to the laryngoscopic views seen on intraoral video during intubation in a pediatric emergency department.
Methods:
This was a retrospective review of prospectively collected observational data of patients undergoing intubation in an academic pediatric emergency department from February 2022 to February 2025. The main outcome was modified CL grade documented in the EMR vs modified CL grade seen on intraoral video. Correctly graded airways were defined as the modified CL grade documented in the EMR matching the best modified CL grade seen on intraoral video.
Results:
Airways were often incorrectly graded, occurring in 68 out of 161 attempts (42.2%). The most common CL grade discrepancy was documentation of a grade 1 view in the EMR when the best view on video was grade 2a or 2b (n = 63).
Conclusion:
Future airway research must account for potential inaccuracies in self-reported laryngoscopic views and/or inconsistencies between the use of the original versus modified CL airway grading system. More research is needed into which aspects of airway management are inaccurately recorded in the EMR.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....