Selective, effective, and rapid removal of cationic and anionic organic dyes using various tailored polymer-coated

Hawra A AlSabbagh1, Kawthar M AlDamestani1, Wael A Amer1,2

  • 1Department of Chemistry, College of Science, University of Bahrain, Sakhir 32038, Bahrain. khboubbou@uob.edu.bh.

Related Concept Videos

Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
663
Extraction: Advanced Methods00:56

Extraction: Advanced Methods

Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
535
Coagulation01:06

Coagulation

Colloidal solids are solid particles suspended in solution. They are usually negatively charged, attracting a compact primary layer of positively charged ions, which attract more counterions to form an electrical double layer. Electrostatic repulsion between the charged double layers prevents the particles from colliding, stabilizing the colloids. These solids are often undesirable because they can contain toxins that are difficult to remove. Coagulation is a technique that helps aggregate and...
374
Detergent Purification of Membrane Proteins01:18

Detergent Purification of Membrane Proteins

Detergents are used to purify the integral proteins of the membrane. The hydrophobic portion of the detergent can replace membrane phospholipids while solubilizing the membrane proteins. When detergent monomers reach a specific concentration in a solution called critical micelle concentration (CMC), they form micelles. Above CMC, the concentration of the detergent monomers remains in equilibrium with the micelle. The number of detergent monomers present in the CMC varies for each detergent, and...
5.3K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
779