Oximetry-based devices in diagnosis of obstructive sleep apnea: A systematic review and meta-analysis
Eder Leandro da Silva Dantas1, Fernando Gustavo Stelzer1, Wanderley Marques Bernardo2
1Department of Neurosciences and Behavioral Sciences, Faculty of Medicine of Ribeirao Preto (FMRP), University of São Paulo (USP), Ribeirao Preto, Brazil.
Abstract:
Obstructive sleep apnea (OSA) is a common disorder, associated with significant morbidity and mortality. Recently, several oximetry-based devices have been developed to assist with diagnosing OSA. Therefore, this study aims to evaluate the diagnostic performance of these tools compared to PSG. We included studies that evaluated oximetry-based devices in comparison to PSG for OSA diagnosis in adults. 18 selected studies were divided into two subgroups: consumer wearable and medical devices. Overall sensitivity was 97 % (95 % Confidence Interval [CI]: 96-97 %) and specificity, 63 % (95 % CI: 61-65. In the consumer wearable devices subgroup, sensitivity was 93 % (95 % CI: 90 - 96) and specificity, 63 % (95 % CI: 53 - 71). In the medical devices subgroup, sensitivity was also high as 97 % (95 % CI: 96-97) with a specificity of 63 % (95 % CI: 61-65). Accuracy measured by area under the curve and post-test probability were both 90 %. Oximetry-based devices demonstrate high sensitivity for ruling out OSA in high-risk adults. However, their low specificity raises concerns regarding potential unnecessary healthcare costs. Therefore, these devices may be considered for screening in high-risk individuals, provided that all positive results are confirmed by a gold-standard diagnostic method.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Sleep Apnea
The condition is more prevalent among...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...