Detection of vital signs based on millimeter wave radar
Zhanjun Hao1,2, Yue Wang3, Fenfang Li3
1College of Computer Science and Engineering, Northwest Normal University, Lanzhou, 730070, Gansu, China. haozhj@nwnu.edu.cn.
Abstract:
With the growing demand for health monitoring, non-contact vital signs monitoring technology has garnered widespread attention. While traditional health monitoring methods are accurate, they have limitations in terms of non-contact and non-invasive capabilities. This paper proposes a non-contact vital signs monitoring method based on frequency modulated continuous wave (FMCW) millimeter-wave radar, named MRVS, to enhance both convenience and accuracy. The method consists of three steps: signal processing, decomposition, and reconstruction. Firstly, the millimeter-wave radar is used to detect chest movements, extracting both respiration and heartbeat signals. Then, combining signal superposition with phase difference techniques effectively eliminates static clutter and respiratory harmonic interference, enhancing the signal. Next, discrete wavelet transform (DWT) is utilized to suppress clutter and noise further, performing signal decomposition. The reconstruction module employs an adaptive Kalman filter (AKF) combined with square root normalization for accurate heart rate estimation. Experimental results demonstrate that this method achieves an estimation error rate of less than 7% under different distances, angles, and postures, showcasing high accuracy and robustness and providing a new solution for non-contact vital signs monitoring.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Doppler Effect - II
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation