Related Experiment Video
Updated: Sep 13, 2025

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
Published on: November 23, 2012
Total-body 18F-FDG PET/CT: more choices to promote clinical scanning efficiency
Jie Xiao1,2,3, Shuguang Chen1,2,3, Xiaoguang Hou1,2,3
1Department of Nuclear Medicine, Zhongshan Hospital, 180 Fenglin Rd, Shanghai, China.
Background:
The study aims to maximize clinical scan efficiency for Total-body (TB) 18F-FDG PET/CT systems by optimizing scan strategies based on theoretical models and clinical experience from a single center.
Results:
This prospective study include two parts. The first part involved simulation experiments using theoretical models to maximize patient throughput and/or minimizing radiotracer activity across four clinical scanning scenarios: fixed working time, predetermined radiotracer activity, integration of various injection activity regimens for a fixed number of patients, and incorporation of dynamic scans into routine static scans within a fixed working time. The optimal scan strategies for these scenarios were then proposed. The second part validated the estimated throughput results through high-throughput tests performed in the real clinical settings with an fixed working time of 8 h. Under a fixed working time of 8 h, the theoretical patient throughput for full-activity, half-activity, 1/3-activity, and 1/10-activity injection regimens was 60, 48, 43, 30 patients, respectively. The corresponding real clinical throughput achieved was 60, 49, 48, 28 patients. For a total 18F-FDG activity of 37,000 to 148,000 MBq (1 to 4 Ci), the 1/3-activity injection regimen yielded the highest patient throughput, ranging 52 to 72 patients. Strategically combining various injection activity regimens could reduce radiotracer activity consumption. Additionally, placing full-activity dynamic scans after routine static scans for full-activity, half-activity, and 1/3-activity, and before 1/10 activity, proved to ba more economical strategies.
Conclusions:
Optimized scan strategies for typical clinical scenarios of TB 18F-FDG PET/CT systems were proposed, which could promote clinical scan efficiency and accommodate diverse clinical requirements. These strategies enable centers to balance throughput and activity efficiency while maintaining diagnostic quality.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...